Table 2 |
||||||
|
Decrease in Influenza Virus Survival due to Humidification, based on CONTAM Output |
||||||
|
Heating Type |
Modeled Domain1 |
No Humidification |
Humidification |
Decrease in Airborne Virus Survival due to Humidification (% change) |
||
|
|
||||||
|
Median hourly RH2 |
Median hourly AH (VP, mb)2 |
Median hourly RH2 |
Median hourly AH (VP, mb)2 |
|||
|
|
||||||
|
Bedroom Humidifier Scenario |
||||||
|
|
||||||
|
Forced Air |
bedroom |
27 |
5.4 |
38 |
7.7 |
17.5 |
|
|
|
|||||
|
Radiant |
34 |
6.9 |
53 |
10.7 |
31.6 |
|
|
|
||||||
|
Multiple Humidifier Scenario3 |
||||||
|
|
||||||
|
Forced Air |
1st floor |
26 |
5.2 |
29 |
5.8 |
7.8 |
|
|
||||||
|
2nd floor |
27 |
5.4 |
33 |
6.6 |
8 |
|
|
|
||||||
|
Radiant |
1st floor |
33 |
6.6 |
40 |
8.1 |
9.5 |
|
|
||||||
|
2nd floor |
36 |
7.3 |
48 |
9.7 |
13.9 |
|
|
|
||||||
|
1 1st floor and 2nd floor are floor level averages 2 Evening hour median levels (7 PM to 10 AM) 3 Humidifiers in all bedrooms and family room |
||||||
|
Myatt et al. Environmental Health 2010 9:55 doi:10.1186/1476-069X-9-55 |
||||||